Summary for Test 2023-11-14-104-1

Test performed: ASTM C136-19

Project Information

Project IdentifiersProject ID: 994326
DEA: 051C3604
EFIS: 0512000134
DIST-CO-RTE-PM05-SB-217-0.9/1.4
Award Date01/31/2023
Closeout DateNot set
Work DescriptionREPLACE BRIDGE.
Location DescriptionSANTA BARBARA COUNTY NEAR GOLETA FROM 0.2 MILE EAST OF GOLETA SLOUGH BRIDGE TO 0.4 MILE EAST OF SAN JOSE CREEK BRIDGE
QA Service Level1 (Verified on 10/17/2022)

Sample Information

Sample Taken Date11/14/2023 Sample Unique Key104
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/06/2023
Sample typeQuality Control A brief description of the sampleQC Weekly Aggregate Data
The quantity of what the sample constitutes24 CY From where was the sample collectedFabricator
First name of sampler or witnessed byJason Last name of sampler or witnessed byAllen
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameKie-Con Antioch Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-07-0003
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-11-14-104
DIME Test ID: 2023-11-14-104-1
Testing Lab: Kie-Con, Incorporated - Antioch
Test Method: ASTM C136-19: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2024-09-17

Test Results


What type of gradation is being tested?: 0.5 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Individual Mass Retained
Has the fine aggregate sample been reduced? (question for combined gradation type): No
Input Type: Calculated
Tester's full name: Connor Pelan
Date of test: 11/14/2023
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 73.7 %
Cumulative percent passing the 3/8 in. sieve: 31.1 %
Cumulative percent passing the #4 sieve: 2.4 %
Cumulative percent passing the #8 sieve: 1.1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/17/2024