Summary for Test 2024-09-05-76-3
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 994331 DEA: 11430254 EFIS: 1118000079 |
---|---|
DIST-CO-RTE-PM | 11-SD-52-5.1/9.0 |
Award Date | 12/21/2023 |
Closeout Date | Not set |
Work Description | CONST AUX LANE, COMPACTION GROUTING, RHMA, LANDSCAPE, & ELECTRICAL. |
Location Description | SAN DIEGO COUNTY IN SAN DIEGO FROM 0.4 MILE WEST OF CONVOY STREET OVERCROSSING TO 0.3 MILE EAST OF SANTO ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 02/05/2024) |
Sample Information
Sample Taken Date | 09/05/2024 | Sample Unique Key | 76 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/09/2024 |
Sample type | Quality Assurance | A brief description of the sample | HMA |
The quantity of what the sample constitutes | 4 boxes | From where was the sample collected | Source |
First name of sampler or witnessed by | Ben | Last name of sampler or witnessed by | Smith |
Title of sampler | Telephone number of sampler | 619 380 4522 | |
Laboratory sample identification | 0804-A | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Martin Marietta | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | 23417005SR |
Test Details
DIME Sample ID: 2024-09-05-76
DIME Test ID: 2024-09-05-76-3
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-09-27
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 09/17/2024
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7475.6 grams
Mass of oven-dry sample in air for Sample 1: 2546.5 grams
Mass of container filled with the sample and water for Sample 1: 8995.1 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.48
Theoretical maximum density at 25°C (77°F): 154.4 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/27/2024 ✔