Summary for Test 2024-09-15-7-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000206 DEA: 033G2704 EFIS: 0324000079 |
|---|---|
| DIST-CO-RTE-PM | 03-SUT-99-8.3/14.1 |
| Award Date | 06/27/2024 |
| Closeout Date | 04/23/2025 |
| Work Description | REPLACE PAVEMENT. |
| Location Description | SUTTER COUNTY ON ROUTE 99 NEAR NICOLAUS FROM 0.3 MILE NORTH OF ROUTE 70 JUNCTION TO 0.6 MILE SOUTH OF LAUREL AVENUE |
| QA Service Level | 1 (Verified on 04/18/2024) |
Sample Information
| Sample Taken Date | 09/15/2024 | Sample Unique Key | 7 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/16/2024 | Sample type | Quality Assurance |
| A brief description of the sample | 2 Boxes | The quantity of what the sample constitutes | 1/2" RHMA-G |
| From where was the sample collected | Source | First name of sampler or witnessed by | Brad |
| Last name of sampler or witnessed by | McKeehan | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | Daily 24-192 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | George Reed - Elk Horn | |
| Transportation Laboratory (TL) Number | C803821 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 1 |
| Sublot number | 9 | HMA Mix Number | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-09-15-7
DIME Test ID: 2024-09-15-7-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-09-16
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 09/16/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1639.3 g
Mass Loss: 142.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.44 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 8.25 %
General comments (publicly viewable) (Max 1000 characters): R1
OBC 7.8
Test was verified on 9/16/2024 ✔