Summary for Test 2024-09-05-47-4

Test performed: AASHTO T275-07r12

Project Information

Project IdentifiersProject ID: 1000251
DEA: 042Y5004
EFIS: 0423000122
DIST-CO-RTE-PM04-NAP-221-0.2/1.7
Award Date06/12/2024
Closeout DateNot set
Work DescriptionCOLD PLANE ASPHALT CONCRETE PAVEMENT AND OVERLAY WITH RHMA-G.
Location DescriptionNAPA COUNTY IN AND NEAR NAPA FROM 0.2 MILE NORTH OF JUNCTION ROUTE 12/29 TO 0.2 MILE NORTH OF BASALT ROAD UNDERCROSSING
QA Service Level1 (Verified on 06/03/2024)

Sample Information

Sample Taken Date09/05/2024 Sample Unique Key47
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/06/2024
Sample typeQuality Assurance A brief description of the sample3/4"HMA+25%RAP
The quantity of what the sample constitutes0-750 Tons From where was the sample collectedSource
First name of sampler or witnessed byJacob Last name of sampler or witnessed byVega
Title of samplerLab Technician Telephone number of sampler8316826277
Laboratory sample identificationCon_24_661 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Vallejo drier Drum Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number2 HMA Mix Number220304

Test Details

DIME Sample ID: 2024-09-05-47
DIME Test ID: 2024-09-05-47-4
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Test Release Date: 2024-09-18

Test Results


Number of tests: 1
What test procedure is performed?: Method A
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 09/13/2024
Bulk Specific Gravity: 2.358
General comments (publicly viewable) (Max 1000 characters): Vulcan Vallejo Drier Drum Plant

Test was verified on 9/18/2024