Summary for Test 2024-08-29-46-1
Test performed: AASHTO T315-22Project Information
Project Identifiers | Project ID: 1000089 DEA: 024J8904 EFIS: 0223000084 |
---|---|
DIST-CO-RTE-PM | 02-TEH-36-6.0/R12.6 |
Award Date | 04/04/2024 |
Closeout Date | Not set |
Work Description | RHMA (GAP GRADED) OVERLAY WITH REPLACE ASPHALT CONCRETE SURFACING. |
Location Description | TEHAMA COUNTY NEAR PLATINA FROM 3.3 MILES WEST OF VESTAL ROAD TO 2.3 MILES EAST OF DRY CREEK BRIDGE |
QA Service Level | 1 (Verified on 03/18/2024) |
Sample Information
Sample Taken Date | 08/29/2024 | Sample Unique Key | 46 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/06/2024 |
Sample type | Verification | A brief description of the sample | PG 64-16 Binder Oil |
The quantity of what the sample constitutes | 2 cans | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Josh | Last name of sampler or witnessed by | Williams |
Title of sampler | QC | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Knife River | Transportation Laboratory (TL) Number | C858133 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | D79699 | Structure unique identifier | |
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Pacific Northwest Oil - Stockton CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2024-08-29-46
DIME Test ID: 2024-08-29-46-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2024-09-18
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Hamidullah Barati
Date of test: 09/13/2024
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.207 kPa
Phase Angle (δ) (for the 10 cycles): 86.5 degree
Complex Modulus (G*) (for the 10 measurements): 1.716 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.72 kPa
General comments (publicly viewable) (Max 1000 characters): OG
Test was verified on 9/18/2024 ✔