Summary for Test 2024-09-11-20-2

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 1000165
DEA: 09392504
EFIS: 0923000029
DIST-CO-RTE-PM09-INY-395-R17.2/25.8
Award Date06/26/2024
Closeout Date12/02/2024
Work DescriptionHOT MIX ASPHALT (TYPE A), SHOULDER BACKING, & STRIPING.
Location DescriptionINYO COUNTY ABOUT 9 MILES SOUTH OF OLANCHA FROM 0.8 MILE SOUTH OF SYKES ROAD TO 0.3 MILE NORTH OF HAIWEE CANYON ROAD
QA Service Level1 (Verified on 03/18/2024)

Sample Information

Sample Taken Date09/11/2024 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/11/2024
Sample typeAcceptance A brief description of the sample1/2” aggregate
The quantity of what the sample constitutes1 Bag of Coldfeed From where was the sample collectedSource
First name of sampler or witnessed byDylan Last name of sampler or witnessed byCarapazza
Title of samplerConsultant QA Telephone number of sampler
Laboratory sample identificationCF20 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Solari Plant Transportation Laboratory (TL) Number4314
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Granite solari
The fabricator's/manufacturer's product name for the sample1/2” cold feed The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt device at plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Combined Gradation Report Information

Combined Gradation Report IdBin IndexDime Test Id
2024-09-22: HMA Aggregates (Size 1/2"): Type A HMA - Continuous Mixing Plant - Sieve Analysis12024-09-11-20-2

Test Details

DIME Sample ID: 2024-09-11-20
DIME Test ID: 2024-09-11-20-2
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2024-09-13

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Calculated
Tester's full name: Derek Carrington
Date of test: 09/13/2024
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 94.1 %
Cumulative percent passing the 3/8 in. sieve: 75.6 %
Cumulative percent passing the #4 sieve: 47 %
Cumulative percent passing the #8 sieve: 37 %
Cumulative percent passing the #16 sieve: 27.5 %
Cumulative percent passing the #30 sieve: 18.2 %
Cumulative percent passing the #50 sieve: 9.7 %
Cumulative percent passing the #100 sieve: 4.2 %
Cumulative percent passing the #200 sieve: 2.4 %
General comments (publicly viewable) (Max 1000 characters): CF-20 Agg

Test was verified on 9/13/2024