Summary for Test 2017-08-04-2-1
Test performed: ASTM A416-15Project Information
| Project Identifiers | Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-710-6.0-9.4 |
| Award Date | 09/02/2011 |
| Closeout Date | Not set |
| Work Description | Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
| Location Description | Port of Long Beach (District 7) |
| QA Service Level | 1 (Verified on 06/03/2013) |
Sample Information
| Sample Taken Date | 08/04/2017 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/07/2017 |
| Sample type | Quality Assurance | A brief description of the sample | 6/10 x 270 KSI Strand |
| The quantity of what the sample constitutes | 14 packs | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Ramos | Last name of sampler or witnessed by | RAMOS |
| Title of sampler | QA | Telephone number of sampler | 916-996-2658 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S08-022-17 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
|---|---|---|---|
| Reel/Coil/Pack Number(s) | S334180-4 | Number of Coils | 1 |
| Group Number | Unknown | Strand Diameter | .6 in |
| Grade | 270 | Strand Specification | ASTM A 416 |
| Heat Number(s) | S0520317 | Mfg. Lot Number(s) | SIPC171928 |
| Manufacturer(s) | Suniden |
Test Details
DIME Sample ID: 2017-08-04-2
DIME Test ID: 2017-08-04-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2017-08-15
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/08/2017
UTM: 120KIP
Temperature: 72 F
Extensometers: E88766
| Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | S0520317 | S334180-4 | 0.215 | 58851 | 54579 | 28 | 1.85 | Brian |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 8/8/2017 ✔