Summary for Test 2024-09-11-24-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000011
DEA: 061G3904
EFIS: 0623000193
DIST-CO-RTE-PM06-FRE-33-R62.9/R68.5
Award Date04/19/2024
Closeout Date04/07/2025
Work DescriptionRUMBLE STRIPS, COLD PLANE, HOT MIX ASPHALT, AND SHOULDER BACKING.
Location DescriptionFRESNO COUNTY NEAR MENDOTA FROM MAIN LIFT CANAL BRIDGE TO OUTSIDE CANAL BRIDGE
QA Service Level1 (Verified on 01/08/2024)

Sample Information

Sample Taken Date09/11/2024 Sample Unique Key24
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/11/2024
Sample typeQuality Assurance A brief description of the sample3/4” HMA Aggregate
The quantity of what the sample constitutes0-750 Tons Produced From where was the sample collectedManufacturer
First name of sampler or witnessed byNoah Last name of sampler or witnessed byHunt
Title of samplerSenior Materials Tester Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Coalinga HMA Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number1 HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-09-11-24
DIME Test ID: 2024-09-11-24-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-09-13

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 09/12/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 2853.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 5015.7 g
Mass of HMA Sample prior to ignition: 2161.8 g
Mass Loss: 137.6 g
Mass of aggregate remaining after ignition: 2024.2 g
Correction Factor (Percent by mass of HMA Specimen): 1.19 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 5.04 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/13/2024