Summary for Test 2024-08-22-19-2

Test performed: CTM 523-May 2020

Project Information

Project IdentifiersProject ID: 993318
DEA: 11423704
EFIS: 1116000059
DIST-CO-RTE-PM11-SD-8-R31.8/R41.7
Award Date04/01/2022
Closeout Date04/08/2025
Work DescriptionPLACE CRCP, HMA, MGS, AND WATER POLLUTION CONTROL SYSTEM.
Location DescriptionSAN DIEGO COUNTY NEAR ALPINE FROM VIEJAS CREEK BRIDGE TO PINE VALLEY CREEK BRIDGE
QA Service Level1 (Verified on 10/27/2021)

Sample Information

Sample Taken Date08/22/2024 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/23/2024
Sample typeQuality Assurance A brief description of the sampleConcrete
The quantity of what the sample constitutes6 beams From where was the sample collectedJob Site
First name of sampler or witnessed byJesse Last name of sampler or witnessed byGastelum
Title of sampler Telephone number of sampler
Laboratory sample identification6593-B Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberG3-22-PCC 308R
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedNot Privided
Concrete batch plantGranite The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedJob Site Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-08-22-19
DIME Test ID: 2024-08-22-19-2
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2024-09-16

Test Results


Number of specimens: 2
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 09/12/2024
Identification number: 6593-B
Width of specimen: 6.0 inch
Width of specimen 2: 6.0 inch
Depth of specimen: 6.0 inch
Depth of specimen 2: 6.0 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Maximum load applied: 9892 lb
Maximum load applied 2: 11274 lb
Curing history and apparent moisture condition of the specimen: Cure Room
If specimen was capped, ground or if leather shims were used: 0
Defects in specimen: None
Age of specimen: 21 days
Age of specimen in hours: 0 hours
Modulus of rupture: 825 psi
Modulus of rupture 2: 940 psi
Modulus of rupture average: 885 psi
General comments (publicly viewable) (Max 1000 characters): 21 days, 2 Beams, 570 psi @ 28 days

Test was verified on 9/16/2024