Summary for Test 2024-09-03-20-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000179
DEA: 081M8504
EFIS: 0822000054
DIST-CO-RTE-PM08-RIV-111-0.0/18.5
Award Date05/15/2024
Closeout Date01/06/2025
Work DescriptionRHMA (GAP-GRADED), COLD PLANE AC PVMT, THERMOPLASTIC TRAFFIC STRIPE.
Location DescriptionRIVERSIDE COUNTY AT SALTON SEA FROM IMPERIAL COUNTY LINE TO 0.1 MILE NORTH OF 66TH AVENUE
QA Service Level1 (Verified on 05/15/2024)

Sample Information

Sample Taken Date09/03/2024 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/04/2024
Sample typeAcceptance A brief description of the sample3/4" RHMA G SP .5% LAS
The quantity of what the sample constitutes9 BOXES OF RHMA 1 GAL CAN PG64-16 1 GAL CAN OF RBR BLND 1 GAL CAN LAS From where was the sample collectedManufacturer
First name of sampler or witnessed byHECTOR Last name of sampler or witnessed byMM - QC
Title of sampler Telephone number of sampler
Laboratory sample identification0453G-24 Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartin Marietta -Coachella Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number43418180
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-09-03-20
DIME Test ID: 2024-09-03-20-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-09-12

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Dylan Nault
Date of test: 09/10/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2163.7 g
Mass Loss: 162.4 g
Correction Factor (Percent by mass of HMA Specimen): -0.04 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.41 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/12/2024