Summary for Test 2024-09-08-24-2

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 1000251
DEA: 042Y5004
EFIS: 0423000122
DIST-CO-RTE-PM04-NAP-221-0.2/1.7
Award Date06/12/2024
Closeout DateNot set
Work DescriptionCOLD PLANE ASPHALT CONCRETE PAVEMENT AND OVERLAY WITH RHMA-G.
Location DescriptionNAPA COUNTY IN AND NEAR NAPA FROM 0.2 MILE NORTH OF JUNCTION ROUTE 12/29 TO 0.2 MILE NORTH OF BASALT ROAD UNDERCROSSING
QA Service Level1 (Verified on 06/03/2024)

Sample Information

Sample Taken Date09/08/2024 Sample Unique Key24
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/09/2024
Sample typeQuality Assurance A brief description of the sample1/2"RHMA-G
The quantity of what the sample constitutesLOT 1 SUBLOT 2 From where was the sample collectedSource
First name of sampler or witnessed byJacob Last name of sampler or witnessed byVega
Title of samplerLab Technician Telephone number of sampler8316826277
Laboratory sample identificationCon_24_660 Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Woodland batch Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-57-0006
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Stream @ Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number1
Sublot number2 Aggregate Mix Number30640542508P

Test Details

DIME Sample ID: 2024-09-08-24
DIME Test ID: 2024-09-08-24-2
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2024-09-11

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 09/09/2024
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 99 %
Cumulative percent passing the 3/8 in. sieve: 88 %
Cumulative percent passing the #4 sieve: 35 %
Cumulative percent passing the #8 sieve: 15 %
Cumulative percent passing the #16 sieve: 8 %
Cumulative percent passing the #30 sieve: 6 %
Cumulative percent passing the #50 sieve: 4 %
Cumulative percent passing the #100 sieve: 3 %
Cumulative percent passing the #200 sieve: 1.7 %
General comments (publicly viewable) (Max 1000 characters): Teichert Woodland Batch Plant

Test was verified on 9/11/2024