Summary for Test 2024-09-09-25-4

Test performed: AASHTO T269-14

Project Information

Project IdentifiersProject ID: 994616
DEA: 112N1654
EFIS: 1122000152
DIST-CO-RTE-PM11-SD-8-R61.0/R68.0
Award Date06/05/2023
Closeout Date06/11/2024
Work DescriptionPLACE RHMA-G(BWC) OVERLAY, PAVEMENT MARKING, & RUMBLE STRIP.
Location DescriptionSAN DIEGO COUNTY NEAR BOULEVARD FROM 0.1 MILE WEST OF CRESTWOOD ROAD UNDERCROSSING TO 0.2 MILE EAST OF MCCAIN VALLEY ROAD UNDERCROSSING
QA Service Level1 (Verified on 07/18/2023)

Sample Information

Sample Taken Date09/09/2024 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/10/2024
Sample typeQuality Assurance A brief description of the sample1/2" RHMA-A
The quantity of what the sample constitutes12 boxes 2 bags From where was the sample collectedSource
First name of sampler or witnessed byJesse Last name of sampler or witnessed byFuentes
Title of sampler8586881440 Telephone number of sampler
Laboratory sample identification9734-PSU Linked DIME Sample ID2024-09-09-26
The fabricator/manufacturer/facility nameMartin Marrieta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number21218080SR
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-09-09-25
DIME Test ID: 2024-09-09-25-4
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2024-09-13

Test Results


Number of tests: 3
Is the sample lab compacted or field compacted?:
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 09/11/2024
123
2.226 2.219 2.231
2.408

7.6 %

7.8 %

7.4 %

7.6 %
General comments (publicly viewable) (Max 1000 characters): Does not comply - Failed both Height and Air Voids

Test was verified on 9/13/2024