Summary for Test 2024-09-06-30-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 995487
DEA: 043W7604
EFIS: 0422000033
DIST-CO-RTE-PM04-SOL-37-R7.3/R8.0
Award Date03/11/2024
Closeout Date11/27/2024
Work DescriptionPOLYESTER CONCRETE OVERLAY.
Location DescriptionSOLANO COUNTY IN AND NEAR VALLEJO FROM 0.2 MILE EAST OF WALNUT STREET OVERCROSSING TO 0.5 MILE WEST OF SACRAMENTO STREET OVERCROSSING
QA Service Level1 (Verified on 11/27/2023)

Sample Information

Sample Taken Date09/06/2024 Sample Unique Key30
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/10/2024
Sample typeQuality Assurance A brief description of the sample1/2"HMA+25%RAP
The quantity of what the sample constitutes0-750 Tons From where was the sample collectedSource
First name of sampler or witnessed byJacob Last name of sampler or witnessed byVega
Title of samplerLab Technician Telephone number of sampler8316826277
Laboratory sample identificationCon_24_671 Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartin Marietta Sunol Drum Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberL230123
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-09-06-30
DIME Test ID: 2024-09-06-30-2
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-09-11

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 09/09/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1672.4 g
Mass Loss: 105.8 g
Correction Factor (Percent by mass of HMA Specimen): 1.26 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.18 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.89 %
General comments (publicly viewable) (Max 1000 characters): PASSED

Test was verified on 9/11/2024