Summary for Test 2024-09-09-19-2
Test performed: CTM 216-June 2011Project Information
| Project Identifiers | Project ID: 994961 DEA: 07338704 EFIS: 0717000063 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-405-12.9/21.5 |
| Award Date | 03/08/2023 |
| Closeout Date | Not set |
| Work Description | LA-405 Roadside Safety Improvements |
| Location Description | In LA County at various locations from 405/110 separation PM 12.9 to North of 405/105 separation PM 21.5. |
| QA Service Level | 1 (Verified on 07/13/2023) |
Sample Information
| Sample Taken Date | 09/09/2024 | Sample Unique Key | 19 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/09/2024 |
| Sample type | Acceptance | A brief description of the sample | Location 12 Hawthorne blvd loop on ramp to nb405 (mvp) |
| The quantity of what the sample constitutes | 115 sy | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Sopheak | Last name of sampler or witnessed by | Chong |
| Title of sampler | TEC | Telephone number of sampler | 2138170174 |
| Laboratory sample identification | 24-2780 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Location 12 Hawthorne blvd loop on ramp to nb405 (mvp) | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Subgrade |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | various location sugrade | A detailed description of where the material sample was collected | Jobsite |
| Where the material sample would have been placed if not sampled | Jobsite |
Test Details
DIME Sample ID: 2024-09-09-19
DIME Test ID: 2024-09-09-19-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2024-09-10
Test Results
Is oversize material: No
Input Type: Measured
Tester's full name: Sopheak Chong
Date of test: 09/10/2024
In-place wet density: 2.08
Highest adjust wet density: 2.15
% Moisture: 9.5 %
Optimum Moisture: 11.5 %
Relative compaction: 97
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/10/2024 ✔