Summary for Test 2024-08-27-19-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000022
DEA: 051Q4904
EFIS: 0523000037
DIST-CO-RTE-PM05-SLO,SB-166-R30.4/R35.0
Award Date06/12/2024
Closeout Date11/26/2024
Work DescriptionCOLD PLANE AC PAVEMENT AND OVERLAY WITH RHMA-G.
Location DescriptionSANTA BARBARA AND SAN LUIS OBISPO COUNTIES ABOUT 20 MILES EAST OF SANTA MARIA FROM CUYAMA RIVER BRIDGE TO CUYAMA RIVER BRIDGE.
QA Service Level1 (Verified on 01/19/2024)

Sample Information

Sample Taken Date08/27/2024 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing08/27/2024
Sample typeQuality Assurance A brief description of the sample1 box 1/2" RHMA G
The quantity of what the sample constitutes750 Tons From where was the sample collectedSupplier
First name of sampler or witnessed byIsaac Last name of sampler or witnessed byGleffe
Title of sampler Telephone number of sampler8053191237
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGriffith Edmonston Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number1
Sublot number4 HMA Mix Number520
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-08-27-19
DIME Test ID: 2024-08-27-19-1
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-09-10

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Eric Atkins
Date of test: 09/10/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1585.4 g
Mass Loss: 127.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.39 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.67 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/10/2024