Summary for Test 2017-07-27-1-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 07/27/2017 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/27/2017 |
| Sample type | Verification | A brief description of the sample | .500 nuts and washers |
| The quantity of what the sample constitutes | 19200 20000 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Flygare |
| Title of sampler | CA METS QA Inspector | Telephone number of sampler | 8016692984 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B76-112-17 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | n/a |
|---|---|---|---|
| Heat Number(s) | B40065, 10387930 | Nut Mfg. Lot Number(s) | 15-01-005 |
| Washer Mfg. Lot Number(s) | D2656 | Bolt Specification | n/a |
| Bolt Length(s) | n/a | Nut Specification | A563-DH |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 1/2" | Bolt Mfg. Lot Number | n/a |
| Rocap Test Requirement(s) | none | Lubricant Requirements(s) | |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2017-07-27-1
DIME Test ID: 2017-07-27-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-08-15
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/08/2017
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 2A | 15-01-005 | 1/2\" | 21593 | 96.05 | Nut Proof Load | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 8/8/2017 ✔