Summary for Test 2024-09-03-5-10

Test performed: AASHTO T30-19

Project Information

Project IdentifiersProject ID: 993318
DEA: 11423704
EFIS: 1116000059
DIST-CO-RTE-PM11-SD-8-R31.8/R41.7
Award Date04/01/2022
Closeout Date04/08/2025
Work DescriptionPLACE CRCP, HMA, MGS, AND WATER POLLUTION CONTROL SYSTEM.
Location DescriptionSAN DIEGO COUNTY NEAR ALPINE FROM VIEJAS CREEK BRIDGE TO PINE VALLEY CREEK BRIDGE
QA Service Level1 (Verified on 10/27/2021)

Sample Information

Sample Taken Date09/03/2024 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/03/2024
Sample typeQuality Assurance A brief description of the sample1/2" HMA
The quantity of what the sample constitutes 3 bags From where was the sample collectedSource
First name of sampler or witnessed byDerrick Last name of sampler or witnessed byMcCovy
Title of sampler Telephone number of sampler
Laboratory sample identification6595-RPSU Linked DIME Sample ID2024-09-03-4
The fabricator/manufacturer/facility nameMartin Marietta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-37-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-09-03-5
DIME Test ID: 2024-09-03-5-10
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2024-09-10

Test Results


Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: No
Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 09/10/2024
Cumulative Mass RetainedCumulative Percent Passing
1539.9 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
43.4 grams97 %
151.4 grams90 %
440.1 grams71 %
714.8 grams54 %
926.9 grams40 %
1085.5 grams30 %
1230.9 grams20 %
1333.6 grams13 %
1398.4 grams9.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/10/2024