Summary for Test 2024-09-03-26-1

Test performed: AASHTO T59-22

Project Information

Project IdentifiersProject ID: 1000158
DEA: 033G0304
EFIS: 0323000117
DIST-CO-RTE-PM03-SAC-160-L1.4/L7.0
Award Date06/07/2024
Closeout Date03/20/2025
Work DescriptionCOLD PLANE AC PVMT, HMA, & RHMA.
Location DescriptionSACRAMENTO COUNTY NEAR ANTIOCH FROM 0.1 MILE NORTH OF ANTIOCH BRIDGE TO SHERMAN ISLAND EAST LEVEE ROAD
QA Service Level1 (Verified on 04/18/2024)

Sample Information

Sample Taken Date09/03/2024 Sample Unique Key26
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/05/2024
Sample typeAcceptance A brief description of the sampleSS-1H emulsion TACK OIL
The quantity of what the sample constitutes1 jar From where was the sample collectedJob Site
First name of sampler or witnessed byJ Last name of sampler or witnessed byKalkat
Title of samplerTET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUnknown Transportation Laboratory (TL) Number849414
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeSS-1h
Lot NumberNot set Sub LotNot set
Dilution Percentage RateNot set

Test Details

DIME Sample ID: 2024-09-03-26
DIME Test ID: 2024-09-03-26-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2024-09-09

Test Results


How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 09/09/2024
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 142.0 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 118.4 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 142.6 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 119.0 g
Beaker 1 Residue: 47.2 %
Beaker 2 Residue: 47.2 %
Percentage of residue: 47 %
General comments (publicly viewable) (Max 1000 characters): EVAP

Test was verified on 9/9/2024