Summary for Test 2024-07-24-111-3
Test performed: CTM 217-June 2011Project Information
Project Identifiers | Project ID: 993446 DEA: 120J34U4 EFIS: 1218000034 |
---|---|
DIST-CO-RTE-PM | 12-ORA-55,55-29.6,R6.4/10.3 |
Award Date | 05/27/2022 |
Closeout Date | Not set |
Work Description | CONSTR BRIDGES, RW, SW, JPCP, HMA PVMT, DRAINAGE AND ELECT SYSTEMS. |
Location Description | ORANGE COUNTY IN IRVINE, SANTA ANA, AND TUSTIN ON ROUTE 5 AT NEWPORT AVENUE UNDERCROSSING AND ON ROUTE 55 FROM 0.4 MILE NORTH OF ROUTE 55/405 SEPARATION TO 0.1 MILE SOUTH OF ROUTE 5/55 SEPARATION |
QA Service Level | 1 (Verified on 06/24/2022) |
Sample Information
Sample Taken Date | 07/24/2024 | Sample Unique Key | 111 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/25/2024 |
Sample type | Quality Control | A brief description of the sample | 1", 3/8", WCS |
The quantity of what the sample constitutes | 1 Bag | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Anthony | Last name of sampler or witnessed by | Huezo |
Title of sampler | QC Field Technician | Telephone number of sampler | |
Laboratory sample identification | Mix S85C440T18, Set 1 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | National Ready Mix - IRVINE | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | 00-0000 |
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0052 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Set 1 | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Belt Cut |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1 inch |
The concrete mix design number | S85C440T18 | Lot number | 1 |
Sublot number | 1 | Aggregate Mix Number |
Combined Gradation Report Information
Combined Gradation Report Id | Bin Index | Dime Test Id |
---|---|---|
No assigned tests for this sample. |
Test Details
DIME Sample ID: 2024-07-24-111
DIME Test ID: 2024-07-24-111-3
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2024-09-04
Test Results
Number of tests: 1
Input Type: Calculated
Tester's full name: Andrew Uribe
Date of test: 07/25/2024
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 0
Sand reading (test 1): 0
Sand equivalent (test 1): 80
Sand equivalent before temperature correction: 80
Sand equivalent after temperature correction: 80
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/4/2024 ✔