Summary for Test 2024-08-29-23-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 1000063
DEA: 061F8804
EFIS: 0623000106
DIST-CO-RTE-PM06-KIN-41-R39.9/R48.3
Award Date04/03/2024
Closeout DateNot set
Work DescriptionCOLD PLANE, HMA PAVING, AND INDIVIDUAL CONCRETE SLAB REPLACEMENT.
Location DescriptionKINGS COUNTY AT AND NEAR LEMOORE FROM ROUTE 41/198 SEPARATION TO FRESNO COUNTY LINE
QA Service Level1 (Verified on 01/29/2024)

Sample Information

Sample Taken Date08/29/2024 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/29/2024
Sample typeAcceptance A brief description of the sample3 RSC beams
The quantity of what the sample constitutes0-130 Cy From where was the sample collectedJob Site
First name of sampler or witnessed byJose Last name of sampler or witnessed byLopez
Title of samplerTET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAGEE / Vanguard Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberHE4X4BM
The truck number from where the sample was collected1982 The batch plant ticket number from where the sample was collected1
Concrete batch plantVanguard Construction onsite plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedLD # 11, SB panel # 24 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-08-29-23
DIME Test ID: 2024-08-29-23-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2024-09-03

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 09/01/2024
Identification number: Set 1
Width of specimen: 6 inch
Width of specimen 2: 6 inch
Width of specimen 3: 6 inch
Depth of specimen: 6.0625 inch
Depth of specimen 2: 6.125 inch
Depth of specimen 3: 6.0625 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 9600 lb
Maximum load applied 2: 8600 lb
Maximum load applied 3: 9000 lb
Curing history and apparent moisture condition of the specimen: moist
If specimen was capped, ground or if leather shims were used: leather shims
Defects in specimen, including numbers of beams discarded during test: N/A
Age of specimen: 3 days
Age of specimen in hours: no data
Modulus of rupture: 820 psi
Modulus of rupture 2: 720 psi
Modulus of rupture 3: 770 psi
Modulus of rupture average: 770 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/3/2024