Summary for Test 2024-08-27-21-1
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 1000543 DEA: 031N0104 EFIS: 0324000268 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-160-0/0 |
| Award Date | 05/31/2024 |
| Closeout Date | 07/29/2026 |
| Work Description | continuation of emergency project EA 03-4H9504 Delta Moveables. |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 08/28/2024) |
Sample Information
| Sample Taken Date | 08/27/2024 | Sample Unique Key | 21 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/29/2024 | Sample type | Quality Assurance |
| A brief description of the sample | A325 7/8 x 2 3/4 Hex - 2 bolts | The quantity of what the sample constitutes | A325 7/8 x 2 3/4 Hex - 26 Bolts |
| From where was the sample collected | Source | First name of sampler or witnessed by | Nikhil |
| Last name of sampler or witnessed by | Moon | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Bay Bolt | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 10815880, 8000025868, 32028550 | Nut Mfg. Lot Number(s) | W000114586 |
| Washer Mfg. Lot Number(s) | 176212 | Bolt Specification | A325 7/8 x 2 3/4 Hex |
| Bolt Length(s) | 2.75 | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 7/8” | Bolt Mfg. Lot Number | E988J1 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2024-08-27-21
DIME Test ID: 2024-08-27-21-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2024-09-04
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 09/03/2024
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 76572 | Proof Load |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 9/4/2024 ✔