Summary for Test 2024-08-14-80-2

Test performed: ASTM D5329-16

Project Information

Project IdentifiersProject ID: 995514
DEA: 024J8204
EFIS: 0223000077
DIST-CO-RTE-PM02-MOD-299-14.7/20.0
Award Date06/20/2024
Closeout Date11/27/2024
Work DescriptionSCHAFFER MT CHIP - PLACE ASPHALT RUBBER CHIP SEAL WITH REPLACE AC SURFACING.
Location DescriptionMODOC COUNTY NEAR CANBY FROM 0.1 MILE EAST OF COUNTY ROAD 85 TO 1.7 MILES WEST OF ROUTE 139
QA Service Level1 (Verified on 12/29/2023)

Sample Information

Sample Taken Date08/14/2024 Sample Unique Key80
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/28/2024
Sample typeVerification A brief description of the samplepg 58-22
The quantity of what the sample constitutes1 of 1 From where was the sample collectedJob Site
First name of sampler or witnessed bySpencer Last name of sampler or witnessed byCaperton
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAmerican Payment Systems Transportation Laboratory (TL) Number858019
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 58-22 Lot number
Sublot number Asphalt Rubber Binder Mix Number

Test Details

DIME Sample ID: 2024-08-14-80
DIME Test ID: 2024-08-14-80-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2024-08-30

Test Results


Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 08/30/2024
Temperature: 25 C
Ball Penetration (P1): 1 mm
Final Dial reading (F1): 64 mm
Ball Penetration (P2): 1 mm
Final Dial reading (F2): 63 mm
Ball Penetration (P3): 0 mm
Final Dial reading (F3): 62 mm
Resilience 1: 37 %
Resilience 2: 38 %
Resilience 3: 38 %
Average Resilience: 38 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/30/2024