Summary for Test 2024-08-09-1-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 995524
DEA: 021H3604
EFIS: 0216000040
DIST-CO-RTE-PM02-SIS-96-76.8/78.0
Award Date03/22/2024
Closeout Date12/29/2025
Work DescriptionREPLACE BRIDGE.
Location DescriptionSISKIYOU COUNTY NEAR HORSE CREEK FROM 0.4 MILE WEST OF KLAMATH RIVER BRIDGE TO 2.0 MILES WEST OF KOHL CREEK
QA Service Level1 (Verified on 12/27/2023)

Sample Information

Sample Taken Date08/09/2024 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing08/29/2024 Sample typeQuality Assurance
A brief description of the sampleHRC 500 510 Couplers The quantity of what the sample constitutes8 rebar with Mechanical Couplers
From where was the sample collectedFabricator First name of sampler or witnessed byDavid
Last name of sampler or witnessed byAlvarez Title of samplerQuality Assurance Inspector
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCMC Rebar Tracy CA
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#14 Coupler ModelHRC 500-510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)73130162, 73129190/Lots 1-2 Rebar Heat Number(s)3129862, 3129863
Rebar Size 2 Coupler Unique IDTF-17-01

Test Details

DIME Sample ID: 2024-08-09-1
DIME Test ID: 2024-08-09-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2024-08-29

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 08/29/2024
UTM: 400kip
Temperature: 72.00 f
Halo ID: Large
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11No. 14/43mm1-0.04782.2521503695572Ok Necking - Ultimateaauvinen

General comments (publicly viewable) (Max 1000 characters): Ok Necking - Ultimate
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 8/29/2024 ✔