Summary for Test 2024-08-15-71-4

Test performed: AASHTO T51-22

Project Information

Project IdentifiersProject ID: 995055
DEA: 024H0504
EFIS: 0218000080
DIST-CO-RTE-PM02-SHA-273,299-18.5/18.7,24.1/30.3
Award Date11/16/2023
Closeout DateNot set
Work DescriptionPLACE RHMA, HMA, MINOR CONCRETE, AND REPLACE AC SURFACING.
Location DescriptionSHASTA COUNTY IN AND NEAR REDDING ON ROUTE 273 FROM 0.5 MILE NORTH OF SULPHUR CREEK BRIDGE TO 0.2 MILE SOUTH OF TWIN VIEW BOULEVARD AND ON ROUTE 299 FROM 0.2 MILE WEST OF HILLTOP DRIVE TO 0.1 MILE EAST OF HOOTENANNY LANE
QA Service Level1 (Verified on 10/09/2023)

Sample Information

Sample Taken Date08/15/2024 Sample Unique Key71
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/21/2024
Sample typeVerification A brief description of the sample2 CANS OF BINDER
The quantity of what the sample constitutes2 CANS From where was the sample collectedSource
First name of sampler or witnessed byC Last name of sampler or witnessed byB
Title of samplerTET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameValero - Benicia, CA Transportation Laboratory (TL) Number8585509
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA SupplierTullis North state Asphalt
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2024-08-15-71
DIME Test ID: 2024-08-15-71-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2024-08-28

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 08/28/2024
Ductility of test #1 (D1): 85 cm
Ductility of sample: 85 cm
General comments (publicly viewable) (Max 1000 characters): Duct

Test was verified on 8/28/2024