Summary for Test 2024-07-26-93-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 995182
DEA: 120S1504
EFIS: 1219000099
DIST-CO-RTE-PM12-ORA-241-33.6/38.7
Award Date12/15/2023
Closeout Date06/18/2025
Work DescriptionRESTORE AND UPGRADE JUMP-OUT-RAMPS, AND UPGRADE GUARD RAIL SYSTEMS.
Location DescriptionORANGE COUNTY IN ANAHEIM AT VARIOUS LOCATIONS FROM 1.2 MILE NORTH OF SANTIAGO CANYON ROAD TO 0.3 MILE SOUTH OF N241-E91 CONNECTOR OVERCROSSING
QA Service Level1 (Verified on 10/16/2023)

Sample Information

Sample Taken Date07/26/2024 Sample Unique Key93
Date that the sample was received by the laboratory/organization performing the testing07/27/2024 Sample typeQuality Control
A brief description of the samplestructural concrete The quantity of what the sample constitutes2 cylinders
From where was the sample collectedJob Site First name of sampler or witnessed byMatthew
Last name of sampler or witnessed byBaker Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSoldier pile wall JOR 1N (NB 241, PM 38.6)
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1611795
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected31280312
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedSoldier pile wall JOR 1N (NB 241, PM 38.6) Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-07-26-93
DIME Test ID: 2024-07-26-93-1
Testing Lab: Sequoia Consultants
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-08-27

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: John Romero
Date of test: 08/23/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 127440 lb
Maximum load on cylinder 2: 116040 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 4310 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/27/2024 ✔