Summary for Test 2024-08-09-60-4
Test performed: AASHTO T51-22Project Information
Project Identifiers | Project ID: 1000010 DEA: 061F8904 EFIS: 0623000107 |
---|---|
DIST-CO-RTE-PM | 06-TUL-63-4.0/5.5 |
Award Date | 03/20/2024 |
Closeout Date | Not set |
Work Description | COLD PLANE AC PAVEMENT AND PLACE HMA. |
Location Description | TULARE COUNTY IN AND NEAR VISALIA FROM AVENUE 264 TO VISALIA PARKWAY |
QA Service Level | 1 (Verified on 01/08/2024) |
Sample Information
Sample Taken Date | 08/09/2024 | Sample Unique Key | 60 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/19/2024 |
Sample type | Acceptance | A brief description of the sample | PG 70-10 1/2" HMA R15 |
The quantity of what the sample constitutes | 1 Can | From where was the sample collected | Source |
First name of sampler or witnessed by | T. | Last name of sampler or witnessed by | Hall |
Title of sampler | QA | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | STORAGE TANK / ALBINA | Transportation Laboratory (TL) Number | C754923 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 70-10 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | 7 | |
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Albina Asphalt - Chowchilla CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2024-08-09-60
DIME Test ID: 2024-08-09-60-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2024-08-27
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 08/27/2024
Ductility of test #1 (D1): 150 cm
Ductility of sample: 150 cm
General comments (publicly viewable) (Max 1000 characters): DUCT
Test was verified on 8/27/2024 ✔