Summary for Test 2017-07-24-13-2
Test performed: ASTM A416-15Project Information
| Project Identifiers | Project ID: 7428 DEA: 07215944 EFIS: 0700001834 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-5-4.0/5.9 |
| Award Date | 08/23/2012 |
| Closeout Date | 07/02/2021 |
| Work Description | RECONSTRUCT AND WIDEN FREEWAY AND UNDERCROSSING STRUCTURES. |
| Location Description | LOS ANGELES COUNTY IN NORWALK FROM 0.4 MILE SOUTH OF SAN ANTONIO DRIVE UNDERCROSSING TO 0.7 MILE NORTH OF PIONEER BOULEVARD UNDERCROSSING |
| QA Service Level | 1 (Verified on 11/07/2012) |
Sample Information
| Sample Taken Date | 07/24/2017 | Sample Unique Key | 13 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/24/2017 |
| Sample type | Quality Assurance | A brief description of the sample | Pt strand |
| The quantity of what the sample constitutes | 3 | From where was the sample collected | Source |
| First name of sampler or witnessed by | Tory | Last name of sampler or witnessed by | McLaurin |
| Title of sampler | Unknown | Telephone number of sampler | 6616185971 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | 2017-07-24-13 |
| The fabricator/manufacturer/facility name | Schwagger Davis | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L67-161-17 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
|---|---|---|---|
| Reel/Coil/Pack Number(s) | 5916 | Number of Coils | 1 |
| Group Number | Unknown | Strand Diameter | .6 in |
| Grade | 270 | Strand Specification | ASTM A 416 |
| Heat Number(s) | 81200 | Mfg. Lot Number(s) | 201203PSM00029 |
| Manufacturer(s) | Kiswire |
Test Details
DIME Sample ID: 2017-07-24-13
DIME Test ID: 2017-07-24-13-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2017-08-10
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/02/2017
UTM: 120KIP
Temperature: 72 F
Extensometers: E88766
| Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 81200 | 5916 | 0.226 | 61060 | 52980 | 27.5 | 2 | Brian |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 8/3/2017 ✔