Summary for Test 2024-08-07-65-2

Test performed: ASTM D638-Dec14

Project Information

Project IdentifiersProject ID: 994582
DEA: 073203U4
EFIS: 0722000071
DIST-CO-RTE-PM07-LA-91,605-R16.6/R16.8,R0.0/R10.4
Award Date06/20/2023
Closeout DateNot set
Work DescriptionPLACE CONCRETE PAVEMENT AND HIGH FRICTION SURFACE TREATMENT.
Location DescriptionLOS ANGELES COUNTY ON ROUTE 605 FROM 0.2 MILE NORTH OF KATELLA AVENUE UNDECROSSING TO 0.1 MILE NORTH OF TELEGRAPH ROAD UNDERCROSSING AND ON ROUTE 91 FROM 0.4 MILE WEST OF ROUTE 605 UNDERCROSSING TO 0.2 MILE WEST OF ROUTE 605 UNDERCROSSING
QA Service Level1 (Verified on 07/12/2023)

Sample Information

Sample Taken Date08/07/2024 Sample Unique Key65
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/08/2024
Sample typePer Request A brief description of the sample1 gallon can / HFST RESIN
The quantity of what the sample constitutes23100 gallons From where was the sample collectedManufacturer
First name of sampler or witnessed byScott Last name of sampler or witnessed byDistefano
Title of samplerProduct Manager Resins Telephone number of sampler1 201-577-6850
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSika Corporation Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHigh Friction Surface Treatment Mgf. Lot Number(s)A3008955935 B3008955954
Batch NumberA3008955935 B3008955954 Mix NumberA3008955935 B3008955954
Resin Binder TypeEpoxy Used for OverlayYes
Used for InlayNo

Test Details

DIME Sample ID: 2024-08-07-65
DIME Test ID: 2024-08-07-65-2
Testing Lab: Sika Corporation
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Test Release Date: 2024-08-27

Test Results


Number of specimens tested: 5
Input Type: Calculated
Tester's full name: Thao Vu
Date of test: 08/26/2024
Conditioning procedure: 18/25/50+5/70
Speed of testing: 0.45 in/min
Sample 1 Width: 0.5 in
Sample 1 Thickness: 0.151 in
Sample 1 Area: 0.0755 in^2
Sample 1 Ultimate Strength Actual: 216 lbs
Sample 1 percent elongation: 32.5 %
Sample 1 Time: 1 MM:SS
Sample 2 Width: 0.5 in
Sample 2 Thickness: 0.146 in
Sample 2 Area: 0.073 in^2
Sample 2 Ultimate Strength Actual: 207 lbs
Sample 2 percent elongation: 37 %
Sample 2 Time: 1 MM:SS
Sample 3 Width: 0.5 in
Sample 3 Thickness: 0.14 in
Sample 3 Area: 0.07 in^2
Sample 3 Ultimate Strength Actual: 199 lbs
Sample 3 percent elongation: 34.5 %
Sample 3 Time: 1 MM:SS
Sample 4 Width: 0.5 in
Sample 4 Thickness: 0.133 in
Sample 4 Area: 0.0665 in^2
Sample 4 Ultimate Strength Actual: 197 lbs
Sample 4 percent elongation: 31.5 %
Sample 4 Time: 1 MM:SS
Sample 5 Width: 0.5 in
Sample 5 Thickness: 0.132 in
Sample 5 Area: 0.066 in^2
Sample 5 Ultimate Strength Actual: 195 lbs
Sample 5 percent elongation: 30.3 %
Sample 5 Time: 1 MM:SS
Sample 1 Ultimate strength: 2860 psi
Sample 2 Ultimate strength : 2840 psi
Sample 3 Ultimate strength: 2840 psi
Sample 4 Ultimate strength: 2960 psi
Sample 5 Ultimate strength: 2950 psi
Ultimate Strength Average: 2890 psi
Percent Elongation Average: 33.1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/27/2024