Summary for Test 2017-07-24-4-3

Test performed: ASTM A416-15

Project Information

Project IdentifiersProject ID: 7428
DEA: 07215944
EFIS: 0700001834
DIST-CO-RTE-PM07-LA-5-4.0/5.9
Award Date08/23/2012
Closeout Date07/02/2021
Work DescriptionRECONSTRUCT AND WIDEN FREEWAY AND UNDERCROSSING STRUCTURES.
Location DescriptionLOS ANGELES COUNTY IN NORWALK FROM 0.4 MILE SOUTH OF SAN ANTONIO DRIVE UNDERCROSSING TO 0.7 MILE NORTH OF PIONEER BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 11/07/2012)

Sample Information

Sample Taken Date07/24/2017 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing07/24/2017 Sample typeQuality Assurance
A brief description of the sample.6 PT Strand The quantity of what the sample constitutes3
From where was the sample collectedSource First name of sampler or witnessed byTory
Last name of sampler or witnessed byMcLaurin Title of samplerQA
Telephone number of sampler6616185971 Laboratory sample identificationUnknown
Linked DIME Sample ID2017-07-24-4 The fabricator/manufacturer/facility nameSchwagger Davis
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormL67-161-17
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand CommentsUnknown
Reel/Coil/Pack Number(s)5873 Number of Coils1
Group NumberUnknown Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)81200 Mfg. Lot Number(s)201203PSM00029
Manufacturer(s)Kiswire

Test Details

DIME Sample ID: 2017-07-24-4
DIME Test ID: 2017-07-24-4-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2017-08-10

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/01/2017
UTM: 120KIP
Temperature: 72 F
Extensometers: E88766
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
18120058730.226610035255827.22.2Brian

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 8/3/2017 ✔