Summary for Test 2024-07-25-28-8

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 995060
DEA: 081J2604
EFIS: 0818000012
DIST-CO-RTE-PM08-RIV-215-R13.5/R19.5
Award Date01/10/2024
Closeout DateNot set
Work DescriptionRHMA, REPLACE AC SURFACING, ROCK BLANKET, AND COMPOST.
Location DescriptionRIVERSIDE COUNTY IN MURRIETA AND MENIFEE FROM 1.0 MILE NORTH OF CLINTON KEITH ROAD TO 1.0 MILE NORTH OF NEWPORT ROAD
QA Service Level1 (Verified on 08/15/2023)

Sample Information

Sample Taken Date07/25/2024 Sample Unique Key28
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/26/2024
Sample typeVerification A brief description of the sampleJMF Verification
The quantity of what the sample constitutes1can From where was the sample collectedSource
First name of sampler or witnessed byKalpesh Patel / Last name of sampler or witnessed byPatel
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartin Mariett(CCA) Lake Elsinore Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Wilmington CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2024-07-25-28
DIME Test ID: 2024-07-25-28-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2024-08-26

Test Results


Phase: PAV residue
Input Type: Calculated
Tester's full name: Sunday Agude
Date of test: 08/26/2024
Test Plate Diameter: 25 mm
Phase Angle (δ) (for the 10 cycles): 50.8 degree
(G*) x sin(δ)=: 2155 kPa
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/26/2024