Summary for Test 2023-08-25-78-1

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 994309
DEA: 033H5404
EFIS: 0318000012
DIST-CO-RTE-PM03-BUT-70-46.0/47.0
Award Date02/10/2023
Closeout DateNot set
Work DescriptionRAISE ALIGNMENT, PLACE HMA, STRUCTURAL CONCRETE & BRIDGE RAIL.
Location DescriptionBUTTE COUNTY NEAR PARADISE FROM 0.8 MILE WEST OF SHADY REST AREA TO 0.2 MILE EAST OF SHADY REST AREA
QA Service Level1 (Verified on 10/04/2022)

Sample Information

Sample Taken Date08/25/2023 Sample Unique Key78
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/25/2023
Sample typeQuality Control A brief description of the sampleQC Sampling Data
The quantity of what the sample constitutes15 CY From where was the sample collectedJob Site
First name of sampler or witnessed byConnor Last name of sampler or witnessed byPelan
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameKie-Con Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberK4060-14212
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected119365
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete from wheel barrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-08-25-78
DIME Test ID: 2023-08-25-78-1
Testing Lab: Kie-Con, Incorporated - Antioch
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-08-23

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With density determined by dimension measurements
Input Type: Calculated
Tester's full name: Connor Pelan
Date of test: 09/22/2023
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Average cylinder density (to nearest 1 pcf): 0 lb/ft^3
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters): 28 day strength of 9,150 PSI

Test was verified on 8/23/2024