Summary for Test 2024-08-14-39-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 215349 DEA: 081C0824 EFIS: 0816000087 |
---|---|
DIST-CO-RTE-PM | 08-RIV-10-R104.9/R134.2 |
Award Date | 03/24/2021 |
Closeout Date | Not set |
Work Description | PLACE HMA (TYPE A), JPCP AND IMPORTED BORROW. |
Location Description | RIVERSIDE COUNTY FROM ROUTE 10/177 SEPARATION TO 1.1 MILES WEST OF WILEY'S WELL RD OC |
QA Service Level | 1 (Verified on 03/01/2021) |
Sample Information
Sample Taken Date | 08/14/2024 | Sample Unique Key | 39 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/19/2024 |
Sample type | Acceptance | A brief description of the sample | 3/4" HMAA SP R24 1% LSM |
The quantity of what the sample constitutes | 4 BOXES OF HMA, 1 QT PG58-34M | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | ERIBERTO | Last name of sampler or witnessed by | ARAGON |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0410A-24 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Fisher Sand and Gravel-Tempe | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | CA125MA |
Test Details
DIME Sample ID: 2024-08-14-39
DIME Test ID: 2024-08-14-39-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-08-23
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Dylan Nault
Date of test: 08/21/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2126.3 g
Mass Loss: 117 g
Correction Factor (Percent by mass of HMA Specimen): 0 %
Moisture Content: 0 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.36 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/23/2024 ✔