Summary for Test 2024-08-09-60-1
Test performed: AASHTO T315-22Project Information
| Project Identifiers | Project ID: 1000010 DEA: 061F8904 EFIS: 0623000107 |
|---|---|
| DIST-CO-RTE-PM | 06-TUL-63-4.0/5.5 |
| Award Date | 03/20/2024 |
| Closeout Date | 05/09/2025 |
| Work Description | COLD PLANE AC PAVEMENT AND PLACE HMA. |
| Location Description | TULARE COUNTY IN AND NEAR VISALIA FROM AVENUE 264 TO VISALIA PARKWAY |
| QA Service Level | 1 (Verified on 01/08/2024) |
Sample Information
| Sample Taken Date | 08/09/2024 | Sample Unique Key | 60 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/19/2024 |
| Sample type | Acceptance | A brief description of the sample | PG 70-10 1/2" HMA R15 |
| The quantity of what the sample constitutes | 1 Can | From where was the sample collected | Source |
| First name of sampler or witnessed by | T. | Last name of sampler or witnessed by | Hall |
| Title of sampler | QA | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | STORAGE TANK / ALBINA | Transportation Laboratory (TL) Number | C754923 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 70-10 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | 7 | |
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Albina Asphalt - Chowchilla CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2024-08-09-60
DIME Test ID: 2024-08-09-60-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2024-08-27
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Hamidullah Barati
Date of test: 08/22/2024
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.144 kPa
Phase Angle (δ) (for the 10 cycles): 87.2 degree
Complex Modulus (G*) (for the 10 measurements): 1.194 kPa
Test Temperature (Specimen 1): 70.0 C
Dynamic Shear, G*/sin(δ): 1.20 kPa
General comments (publicly viewable) (Max 1000 characters): ORG
Test was verified on 8/27/2024 ✔