Summary for Test 2024-07-25-89-1
Test performed: CTM 643-April 2020Project Information
| Project Identifiers | Project ID: 1000513 DEA: 020J8504 EFIS: 0219000168 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-89-21/R34.622 |
| Award Date | 08/05/2025 |
| Closeout Date | Not set |
| Work Description | MCCLOUD CAPM - PAVEMENT REHABILITATION |
| Location Description | IN SISKIYOU COUNTY AT AND NEAR MCCLOUD FROM 0.1 MILE SOUTH OF MUD CREEK BRIDGE TO ROUTE 5 |
| QA Service Level | 1 (Verified on 08/12/2024) |
Sample Information
| Sample Taken Date | 07/25/2024 | Sample Unique Key | 89 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/29/2024 |
| Sample type | Preliminary | A brief description of the sample | Sand, Silt, Rock and Soil |
| The quantity of what the sample constitutes | 2 bags for Structural Section Recommendations | From where was the sample collected | Source |
| First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Steiner |
| Title of sampler | ADME | Telephone number of sampler | |
| Laboratory sample identification | D79670 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | In Situ | Transportation Laboratory (TL) Number | 891125 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 02-SIS-89-pm 23.0 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2024-07-25-89
DIME Test ID: 2024-07-25-89-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2024-08-22
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 08/21/2024
Minimum soil resistance of the lab measurement: 20000 Ohms
Soil sample temperature: 20.9 C
Soil box constant: 1
pH of soil: 6.00
Minimum soil resistance corrected to 15.5: 22700 Ohm-cm
Minimum soil resistivity at 15.5: 22700 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): pH=6.00, p=22700.Ω∙cm
Test was verified on 8/22/2024 ✔