Summary for Test 2024-07-31-78-3
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 1000504 DEA: 024J9604 EFIS: 0223000091 |
|---|---|
| DIST-CO-RTE-PM | 02--- |
| Award Date | 07/26/2024 |
| Closeout Date | 03/24/2025 |
| Work Description | Digouts at Various Locations |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 08/07/2024) |
Sample Information
| Sample Taken Date | 07/31/2024 | Sample Unique Key | 78 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/31/2024 |
| Sample type | Production Start-Up | A brief description of the sample | 1/2-inch Cold feed |
| The quantity of what the sample constitutes | 1 Bag Coldfeed | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Cindy | Last name of sampler or witnessed by | Bryant |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | D79676B-2 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Tullis Inc. - Northstate Asphalt (Redding CA) | Transportation Laboratory (TL) Number | 858505 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Tullis, Northstate Asphalt, Redding, CA |
|---|---|---|---|
| Aggregate Size | Aggregate Source | ||
| RAP Stockpile | Stockpile Size (tons) | ||
| Reclaimed Asphalt Pavement Mix Number |
Test Details
DIME Sample ID: 2024-07-31-78
DIME Test ID: 2024-07-31-78-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-08-20
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 08/14/2024
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7332.3 grams
Mass of oven-dry sample in air for Sample 1: 1697.3 grams
Mass of container filled with the sample and water for Sample 1: 8378.6 grams
Temperature of Water: 25 °F
Specific Gravity for Sample 1: 2.607
Theoretical maximum density at 25°C (77°F): 2599.4 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmmr=2.607
Test was verified on 8/20/2024 ✔