Summary for Test 2024-08-06-101-2
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 995118 DEA: 031H6304 EFIS: 0316000193 |
---|---|
DIST-CO-RTE-PM | 03-SAC-99-12.7/16.3 |
Award Date | 01/30/2024 |
Closeout Date | Not set |
Work Description | CONSTRUCT TWO AUX LANES, CONC BARRIER, & MODIFY ELECT SYSTEMS. |
Location Description | SACRAMENTO COUNTY IN AND NEAR ELK GROVE FROM 0.1 MILE SOUTH OF ELK GROVE BOULEVARD OVERCROSSING TO CALVINE ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 11/13/2023) |
Sample Information
Sample Taken Date | 08/06/2024 | Sample Unique Key | 101 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/19/2024 |
Sample type | Quality Assurance | A brief description of the sample | 2 Boxes |
The quantity of what the sample constitutes | 3/4" HMA w/ 15% RAP | From where was the sample collected | Source |
First name of sampler or witnessed by | J | Last name of sampler or witnessed by | Aguilar |
Title of sampler | Plant OC | Telephone number of sampler | |
Laboratory sample identification | Daily 24-158 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Teichert Perkins | Transportation Laboratory (TL) Number | C743589 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 2 |
Sublot number | 11 | HMA Mix Number |
Test Details
DIME Sample ID: 2024-08-06-101
DIME Test ID: 2024-08-06-101-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-08-20
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 08/20/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2111.7 g
Mass Loss: 108.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.45 %
Moisture Content: 0 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.68 %
General comments (publicly viewable) (Max 1000 characters): L1
OBC 4.8
Test was verified on 8/20/2024 ✔