Summary for Test 2017-07-21-2-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 7428
DEA: 07215944
EFIS: 0700001834
DIST-CO-RTE-PM07-LA-5-4.0/5.9
Award Date08/23/2012
Closeout Date07/02/2021
Work DescriptionRECONSTRUCT AND WIDEN FREEWAY AND UNDERCROSSING STRUCTURES.
Location DescriptionLOS ANGELES COUNTY IN NORWALK FROM 0.4 MILE SOUTH OF SAN ANTONIO DRIVE UNDERCROSSING TO 0.7 MILE NORTH OF PIONEER BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 11/07/2012)

Sample Information

Sample Taken Date07/21/2017 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing07/24/2017 Sample typeQuality Assurance
A brief description of the sample4 feet one and a half inch Welded Hoops The quantity of what the sample constitutes1 set of 4
From where was the sample collectedFabricator First name of sampler or witnessed byGeorge
Last name of sampler or witnessed byLujan Title of samplerQAI
Telephone number of sampler951 640-5331 Laboratory sample identificationUnknown
Linked DIME Sample ID2017-06-05-3 The fabricator/manufacturer/facility nameRKR Steel Welding
Transportation Laboratory (TL) NumberQC TL101 C950653 Inspector Lot Number from the Transportation Laboratory (TL) FormL36-014-17
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingRetest
Service or UltimateUltimate Rebar Heat Number(s)65026858
Hoop Manufacturer Lot Number(s)5 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop4'-1.5" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerGerdau
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2017-07-21-2
DIME Test ID: 2017-07-21-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-08-01

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/25/2017
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
125A#8/25mm0.797602096230Bar BrokeBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 7/25/2017 ✔