Summary for Test 2024-08-05-75-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 995125 DEA: 101E3004 EFIS: 1018000273 |
|---|---|
| DIST-CO-RTE-PM | 10-SJ-5-32.5/49.8 |
| Award Date | 01/12/2024 |
| Closeout Date | Not set |
| Work Description | REMOVE EXISTING PAVEMENT AND REPLACE WITH CONCRETE PAVEMENT. |
| Location Description | SAN JOAQUIN COUNTY IN AND NEAR STOCKTON FROM 0.2 MILE SOUTH OF HAMMER LANE UNDERCROSSING TO SACRAMENTO COUNTY LINE |
| QA Service Level | 1 (Verified on 09/26/2023) |
Sample Information
| Sample Taken Date | 08/05/2024 | Sample Unique Key | 75 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/06/2024 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4 Type A HMA | The quantity of what the sample constitutes | 4 boxes |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Treven |
| Last name of sampler or witnessed by | Fulkerson | Title of sampler | MREA |
| Telephone number of sampler | Laboratory sample identification | 24-H-82 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Teichert Materials Vernalis | |
| Transportation Laboratory (TL) Number | 042339 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 2 |
| Sublot number | 1 | HMA Mix Number | 24J10 |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-08-05-75
DIME Test ID: 2024-08-05-75-2
Testing Lab: CT D10 - District 10 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-08-15
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Manpreet Singh
Date of test: 08/15/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1997.2 g
Mass Loss: 118.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.84 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.12 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 4.95 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/15/2024 ✔