Summary for Test 2024-08-13-28-3

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 1000010
DEA: 061F8904
EFIS: 0623000107
DIST-CO-RTE-PM06-TUL-63-4.0/5.5
Award Date03/20/2024
Closeout DateNot set
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACE HMA.
Location DescriptionTULARE COUNTY IN AND NEAR VISALIA FROM AVENUE 264 TO VISALIA PARKWAY
QA Service Level1 (Verified on 01/08/2024)

Sample Information

Sample Taken Date08/13/2024 Sample Unique Key28
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing08/12/2024
Sample typeAcceptance A brief description of the sampleHMA
The quantity of what the sample constitutesL1SL13 From where was the sample collectedSource
First name of sampler or witnessed byT Last name of sampler or witnessed byHall
Title of samplerMaterials Tester Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameJaxon Baker/Deer Creek Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-54-0021
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedcoldfeed
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number1
Sublot number13 Aggregate Mix Number

Test Details

DIME Sample ID: 2024-08-13-28
DIME Test ID: 2024-08-13-28-3
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2024-08-13

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Calculated
Tester's full name: Kulwinder Rai
Date of test: 08/13/2024
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 95 %
Cumulative percent passing the 3/8 in. sieve: 87 %
Cumulative percent passing the #4 sieve: 58 %
Cumulative percent passing the #8 sieve: 35 %
Cumulative percent passing the #16 sieve: 22 %
Cumulative percent passing the #30 sieve: 15 %
Cumulative percent passing the #50 sieve: 9 %
Cumulative percent passing the #100 sieve: 7 %
Cumulative percent passing the #200 sieve: 5.5 %
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-1F8904_37014_240813_L1SL13_T027_HMApdf117.32 KB08/13/20242024-08-13-28-3   Info

Test was verified on 8/13/2024