Summary for Test 2024-06-14-81-2
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 993333 DEA: 04264724 EFIS: 0419000068 |
|---|---|
| DIST-CO-RTE-PM | 04-MRN-101-R20.8/27.1 |
| Award Date | 04/26/2022 |
| Closeout Date | Not set |
| Work Description | CIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL. |
| Location Description | MARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE |
| QA Service Level | 1 (Verified on 11/01/2021) |
Sample Information
| Sample Taken Date | 06/14/2024 | Sample Unique Key | 81 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/14/2024 |
| Sample type | Quality Assurance | A brief description of the sample | AS-2 |
| The quantity of what the sample constitutes | 15750 sqft | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Cody | Last name of sampler or witnessed by | Cordero |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Pet-24-222 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Roadway ex | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | STA 286+00-290+50 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2024-06-14-81
DIME Test ID: 2024-06-14-81-2
Testing Lab: CT D04 - Petaluma Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-08-12
Test Results
Method Type:: Standard Count
Number of Tests:: 5
Common Test Maximum Used:: No
Input Type: Calculated
Tester's full name: Cody Cordero
Date of test: 06/14/2024
Sum of Count or Density: 362476 g/cc
Average of Count or Density: 72495 g/cc
Sum of Moisture Count: 10578 g/cc
Average of Moisture Count: 2116 g/cc
Count Ratio Density: 2.18
Count Ratio Moisture: 0.22
Calculated Percent Relative Compaction: 95 %
Reported Percent Relative Compaction: 95 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/12/2024 ✔