Summary for Test 2024-06-17-82-3

Test performed: CTM 521-June 2012

Project Information

Project IdentifiersProject ID: 995217
DEA: 061F6904
EFIS: 0623000144
DIST-CO-RTE-PM06-TUL-190-38/57, 39/47, 32/57
Award Date02/13/2023
Closeout Date11/10/2025
Work DescriptionEmergency Landslide Repair. Roadway / Slope / Culvert repairs.
Location DescriptionNot set
QA Service Level1 (Verified on 10/13/2023)

Sample Information

Sample Taken Date06/17/2024 Sample Unique Key82
Date that the sample was received by the laboratory/organization performing the testing06/18/2024 Sample typeAcceptance
A brief description of the samplePCC cylinders retaining wall The quantity of what the sample constitutesUnknown Quantity
From where was the sample collectedJob Site First name of sampler or witnessed byAngelica
Last name of sampler or witnessed byZarate Title of samplerSTRUCTURAL INSPECTOR
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCollected at jobsite
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number185811
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedUnknown
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-06-17-82
DIME Test ID: 2024-06-17-82-3
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-08-09

Test Results


Number of specimens: 3
Input Type: Measured
Tester's full name: Jason Ruiz
Date of test: 07/15/2024
Cylinder Diameter, Cylinder 1 (measurement 1): 4 in
Cylinder Diameter, Cylinder 1 (measurement 2): 4 in
Cylinder Diameter, Cylinder 2 (measurement 1): 4 in
Cylinder Diameter, Cylinder 2 (measurement 2): 4 in
Cylinder Diameter, Cylinder 3 (measurement 1): 4 in
Cylinder Diameter, Cylinder 3 (measurement 2): 4 in
Maximum Load, Cylinder 1: 61124 lb
Maximum Load, Cylinder 2: 58491 lb
Maximum Load, Cylinder 3: 62101 lb
Correction factor: 1
Cylinder Age: 28 days
Break Description of Cylinder 1 (if not 'cone'): 2
Break Description of Cylinder 2 (if not 'cone'): 1
Break Description of Cylinder 3 (if not 'cone'): 2
Average Diameter, Cylinder 1: 4 in
Average Diameter, Cylinder 2: 4 in
Average Diameter, Cylinder 3: 4 in
Cross-Sectional Area of Cylinder 1: 12.57 in^2
Cross-Sectional Area of Cylinder 2: 12.57 in^2
Cross-Sectional Area of Cylinder 3: 12.57 in^2
Average Compressive Strength (to nearest 10): 4820 lb/in^2
Compressive Strength of Cylinder 1: 4862.69 lb/in^2
Compressive Strength of Cylinder 2: 4653.22 lb/in^2
Compressive Strength of Cylinder 3: 4940.41 lb/in^2
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/9/2024 ✔