Summary for Test 2024-07-31-45-1

Test performed: AASHTO T315-22

Project Information

Project IdentifiersProject ID: 1000090
DEA: 024J9204
EFIS: 0223000087
DIST-CO-RTE-PM02-TRI-299-61.0/64.0,70.0/72.2
Award Date04/16/2024
Closeout Date11/27/2024
Work DescriptionASPHALT RUBBER CHIP SEAL WITH REPLACE ASPHALT CONCRETE SURFACING.
Location DescriptionTRINITY COUNTY NEAR DOUGLAS CITY FROM STEEL BRIDGE ROAD TO 1.5 MILES WEST OF GRASS VALLEY CREEK BRIDGE NO 05-0013 AND FROM 2.6 MILES EAST OF TRINITY DAM BOULEVARD TO THE SHASTA COUNTY LINE
QA Service Level1 (Verified on 03/18/2024)

Sample Information

Sample Taken Date07/31/2024 Sample Unique Key45
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/06/2024
Sample typeProduction Start-Up A brief description of the samplePG 58-22 Binder
The quantity of what the sample constitutes2 Cans From where was the sample collectedSource
First name of sampler or witnessed byC Last name of sampler or witnessed byBryant
Title of samplerTET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID2024-07-31-79
The fabricator/manufacturer/facility nameValero - Benicia Transportation Laboratory (TL) NumberC858505
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA SupplierTullis Northstate Asphalt
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2024-07-31-45
DIME Test ID: 2024-07-31-45-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2024-08-21

Test Results


Phase: Original binder
Input Type: Measured
Tester's full name: Hamidullah Barati
Date of test: 08/08/2024
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.254 kPa
Phase Angle (δ) (for the 10 cycles): 83.9 degree
Complex Modulus (G*) (for the 10 measurements): 2.106 kPa
Test Temperature (Specimen 1): 58.0 C
Dynamic Shear, G*/sin(δ): 2.12 kPa
General comments (publicly viewable) (Max 1000 characters): OG#1

Test was verified on 8/21/2024