Summary for Test 2017-07-05-3-2
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 07/05/2017 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/14/2017 |
| Sample type | Quality Assurance | A brief description of the sample | Anchor Bolt Assembly |
| The quantity of what the sample constitutes | 117 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | William | Last name of sampler or witnessed by | Clifford |
| Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 5103253065 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | AM Nut and Bolt | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L78-025-17 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 3066882 | Nut Mfg. Lot Number(s) | 383997A |
| Washer Mfg. Lot Number(s) | 300273 | Bolt Specification | F1554 Gr55 |
| Bolt Length(s) | 36" | Nut Specification | A194 |
| Washer Specification | F436 | Finish | Hot Dip Galvanized |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 3066882 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2017-07-05-3
DIME Test ID: 2017-07-05-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-07-31
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/20/2017
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1B | L9602517 | 1-8 HEX | 109200 | 485.74 | Nut Proof | Fred |
General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Partner Data Point FileTest was verified on 7/24/2017 ✔