Summary for Test 2024-07-24-4-1

Test performed: ASTM A416-18

Project Information

Project IdentifiersProject ID: 212800
DEA: 100G8304
EFIS: 1012000316
DIST-CO-RTE-PM10-MER-152,140,152-Var
Award Date10/31/2023
Closeout Date06/23/2026
Work DescriptionMERCED SEISMIC RESTORATION
Location DescriptionIN MERCED COUNTY ON STATE ROUTES, 59, 140 AND 152 AT VARIOUS BRIDGES.
QA Service Level1 (Verified on 12/20/2018)

Sample Information

Sample Taken Date07/24/2024 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing07/31/2024 Sample typeQuality Assurance
A brief description of the sample ASTM A416 0.6 seven wire uncoated steel strand The quantity of what the sample constitutesOne Pack 60,244 lbs.
From where was the sample collectedSource First name of sampler or witnessed byOsiel
Last name of sampler or witnessed byRamirez Title of samplerQuality Assurance Inspector
Telephone number of sampler(916)767-3535 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameOldcastle Infrastructure
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL123-065-24
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s)S380617-4 Number of Coils1
Group Number4 Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0565024 Mfg. Lot Number(s)SIPC241971
Manufacturer(s)Sumiden Wire Products Corporation

Test Details

DIME Sample ID: 2024-07-24-4
DIME Test ID: 2024-07-24-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2024-08-14

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: AAuvinen
Date of test: 08/07/2024
UTM: 120kip
Temperature: 72 f
Extensometers: E88766
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0565024S380617-40.2185988254644.028.72.06AAuvinen

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 8/14/2024 ✔