Summary for Test 2017-07-14-4-1
Test performed: ASTM F606-14Project Information
| Project Identifiers | Project ID: 211797 DEA: 080G8424 EFIS: 0814000184 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-15-R107.3 |
| Award Date | 12/29/2016 |
| Closeout Date | 06/23/2021 |
| Work Description | UPGRADE EXISTING SAFETY ROADSIDE REST AREAS (SRRA) |
| Location Description | SAN BERNARDINO COUNTY ABOUT 30 MILES EAST OF BARSTOW AT C.V. KANE SAFETY ROADSIDE REST AREA |
| QA Service Level | 1 (Verified on 02/08/2017) |
Sample Information
| Sample Taken Date | 07/14/2017 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/18/2017 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4 inch and 1inch hex head bolts |
| The quantity of what the sample constitutes | unknown | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Ken | Last name of sampler or witnessed by | Varela |
| Title of sampler | Associate Steel Inspector | Telephone number of sampler | (562) 229-9279 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | R and D Fasteners | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L08-070-17 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
|---|---|---|---|
| Heat Number(s) | 2059645 and PL16205614 | Nut Mfg. Lot Number(s) | N/A |
| Washer Mfg. Lot Number(s) | N/A | Bolt Specification | F1554 gr. 36 |
| Bolt Length(s) | varies | Nut Specification | N/A |
| Washer Specification | N/A | Finish | hot-dip galvanized |
| Diameter/Size | 3/4" and 1" | Bolt Mfg. Lot Number | 74934/1 and 74934/5 |
| Rocap Test Requirement(s) | None | Lubricant Requirements(s) | None |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2017-07-14-4
DIME Test ID: 2017-07-14-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2017-07-31
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/20/2017
UTM: 400KIP
Temperature: 72
| Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1A | F1554 Headed Anchor 3/4\" x 25 1/4\" | 0.334 | 26418 | 117 | 79096 | 61472 | 20532 | F1554 10 deg Wedge |
General comments (publicly viewable) (Max 1000 characters): F1554 10 deg Wedge
Test Graph
Source: Partner Data Point FileTest was verified on 7/24/2017 ✔