Summary for Test 2024-07-25-63-5

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 994443
DEA: 053307C4
EFIS: 0514000028
DIST-CO-RTE-PM05-SLO-41,46-44.5/45.3,54.0/57.8
Award Date02/27/2023
Closeout DateNot set
Work DescriptionWye Segment - Route 41/46 Separation
Location DescriptionNot set
QA Service Level1 (Verified on 12/16/2022)

Sample Information

Sample Taken Date07/25/2024 Sample Unique Key63
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/25/2024
Sample typeQuality Control A brief description of the sample1x4 concrete aggregates
The quantity of what the sample constitutes1 per batch From where was the sample collectedSupplier
First name of sampler or witnessed byRickey Last name of sampler or witnessed byGuevara
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHoliday Rock - Paso Robles Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-42-0003
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedstockpile or belt cut
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-07-25-63
DIME Test ID: 2024-07-25-63-5
Testing Lab: Sequoia Consultants
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2024-08-06

Test Results


What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: Yes
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Rickey Guevara
Date of test: 07/25/2024
Cumulative percent passing the 3/8 in. sieve: 100 %
Cumulative percent passing the #4 sieve: 98 %
Cumulative percent passing the #8 sieve: 89 %
Cumulative percent passing the #16 sieve: 79 %
Cumulative percent passing the #30 sieve: 55 %
Cumulative percent passing the #50 sieve: 26 %
Cumulative percent passing the #100 sieve: 9 %
Cumulative percent passing the #200 sieve: 3.3 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/6/2024