Summary for Test 2024-07-16-83-5

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 214639
DEA: 040A7704
EFIS: 0400020155
DIST-CO-RTE-PM04-ALA-80-6.4/6.7
Award DateNot set
Closeout Date03/18/2025
Work DescriptionModify Gilman St IC in Berkeley
Location DescriptionBoth sides of I-80/Gilman St intersections
QA Service Level1 (Verified on 01/24/2020)

Sample Information

Sample Taken Date07/16/2024 Sample Unique Key83
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/16/2024
Sample typeQuality Assurance A brief description of the sample3/8 Rock-Elliot sand +Orca Sand
The quantity of what the sample constitutes3 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byJose Leon Last name of sampler or witnessed byAmparan
Title of sampler Telephone number of sampler8317060175
Laboratory sample identificationRich_24_088 Linked DIME Sample ID
The fabricator/manufacturer/facility nameREADY MIX-OAK-Kennedy St Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0009
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberDDJ118K3 Lot number
Sublot number Aggregate Mix NumberDDJ118K3

Test Details

DIME Sample ID: 2024-07-16-83
DIME Test ID: 2024-07-16-83-5
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2024-08-06

Test Results


Number of tests: 1
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 07/16/2024
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 4.5
Sand reading (test 1): 4
Sand equivalent (test 1): 89
Sand equivalent before temperature correction: 89
Sand equivalent after temperature correction: 89
General comments (publicly viewable) (Max 1000 characters): Elliott sand

Test was verified on 8/6/2024