Summary for Test 2024-07-29-27-3

Test performed: AASHTO T315-22

Project Information

Project IdentifiersProject ID: 995051
DEA: 023H6804
EFIS: 0218000006
DIST-CO-RTE-PM02-SHA-5-R28.8/R44.1
Award Date10/26/2023
Closeout Date09/24/2025
Work DescriptionPLACE RHMA, PAINT TRAFFIC STRIPE, & INSTALL FIBER OPTIC CABLE SYSTEM.
Location DescriptionSHASTA COUNTY ABOUT 6 MILES NORTH OF SHASTA LAKE CITY FROM PIT RIVER BRIDGE TO 1.2 MILES SOUTH OF DOG CREEK BRIDGE
QA Service Level1 (Verified on 08/14/2023)

Sample Information

Sample Taken Date07/29/2024 Sample Unique Key27
Date that the sample was received by the laboratory/organization performing the testing08/01/2024 Sample typeProduction Start-Up
A brief description of the samplePG 58-22 3/4"HMA W/23.6% RAP The quantity of what the sample constitutes2 cans
From where was the sample collectedJob Site First name of sampler or witnessed byC
Last name of sampler or witnessed by BRYINT Title of samplerTET
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameValero
Transportation Laboratory (TL) NumberC853422 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2024-07-29-27
DIME Test ID: 2024-07-29-27-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2024-08-07

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Hamidullah Barati
Date of test: 08/06/2024
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 36.752 kPa
Phase Angle (δ) (for the 10 cycles): 47.8 degree
Complex Modulus (G*) (for the 10 measurements): 3656.729 kPa
Test Temperature (Specimen 1): 22.0 C
(G*) x sin(δ)=: 2709 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 8/7/2024 ✔