Summary for Test 2024-08-01-51-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 995255 DEA: 041J9604 EFIS: 0414000403 |
---|---|
DIST-CO-RTE-PM | 04-MRN,-1-22.8/33.0,45.0/50.5 |
Award Date | 02/13/2024 |
Closeout Date | Not set |
Work Description | COLD PLANE, RHMA, HMA, MGS, CURB RAMPS, SIDEWALKS, AND CULVERTS. |
Location Description | MARIN COUNTY IN AND NEAR POINT REYES STATION FROM FIVE BROOKS TO 1.9 MILES NORTH OF CYPRESS ROAD AND IN AND NEAR TOMALES FROM 0.2 MILES SOUTH OF TOMALES TO 4.4 MILES NORTH OF TOMALES |
QA Service Level | 1 (Verified on 10/18/2023) |
Sample Information
Sample Taken Date | 08/01/2024 | Sample Unique Key | 51 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/01/2024 |
Sample type | Quality Assurance | A brief description of the sample | Class 2 Aggregate Base |
The quantity of what the sample constitutes | 6x12 Cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Jose Leon | Last name of sampler or witnessed by | Amparan |
Title of sampler | TET CT | Telephone number of sampler | 8317060175 |
Laboratory sample identification | Rich_24_094 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Subgrade | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Subgrade |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | shoulder @ job site | |
Where the material sample would have been placed if not sampled | yes |
Test Details
DIME Sample ID: 2024-08-01-51
DIME Test ID: 2024-08-01-51-1
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-08-06
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 08/01/2024
Sum of Count or Density: 136039 g/cc
Average of Count or Density: 45346 g/cc
Sum of Moisture Count: 7296 g/cc
Average of Moisture Count: 2432 g/cc
Count Ratio Density: 34504
Count Ratio Moisture: 9159
Calculated Percent Relative Compaction: 94.5 %
Reported Percent Relative Compaction: 95 %
General comments (publicly viewable) (Max 1000 characters): Subgrade Compaction passed
Test was verified on 8/6/2024 ✔