Summary for Test 2023-12-26-9-2
Test performed: CTM 217-June 2011Project Information
Project Identifiers | Project ID: 993671 DEA: 07357704 EFIS: 0719000097 COOP: 075245 |
---|---|
DIST-CO-RTE-PM | 07-LA-I-210- |
Award Date | 02/14/2023 |
Closeout Date | Not set |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 2 (Verified on 04/04/2022) |
Sample Information
Sample Taken Date | 12/26/2023 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/26/2023 |
Sample type | Quality Control | A brief description of the sample | 1x4 concrete aggregates |
The quantity of what the sample constitutes | 1 per batch | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Justin | Last name of sampler or witnessed by | Gonzalez |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | National Ready Mix - Irwindale | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0052 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | stockpile or belt cut | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-12-26-9
DIME Test ID: 2023-12-26-9-2
Testing Lab: Sequoia Consultants
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2024-08-05
Test Results
Number of tests: 2
Input Type: Calculated
Tester's full name: Jonathan Casanova
Date of test: 12/26/2023
Temperature correction: 0
Temperature of solution: 77
Clay reading (test 1): 5.5
Sand reading (test 1): 4.7
Clay reading (test 2): 5.5
Sand reading (test 2): 4.7
Sand equivalent (test 1): 86
Sand equivalent (test 2): 86
Sand equivalent before temperature correction: 86
Sand equivalent after temperature correction: 86
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/5/2024 ✔